From Name
Michael E. Kitto

Tony - below is text from one of my papers that gives the formula, and an example for you to check that you're calculating correctly.  For Rn-222, I calculate that 1 Bq (60 dpm) is 1.75 E-16 grams   or  6.5 E-18 grams per pCi.  This formula works for all radionuclides, just make sure the units are consistent (half-life in minutes if using dpm activity).   The formula and text below explains why, even though U-238 comprises nearly all of the U mass, its activity is equivalent to U-234 (due to its shorter half-life).  - Mike Kitto
Tony McDonald ---06/11/2012 02:41:08 PM---All, I know pCi/l is a measure of radio activity and PPB is a measure of volume.
From: Tony McDonald
To: RADONPROFESSIONALS@LIST.UIOWA.EDU
Date: 06/11/2012 02:41 PM
Subject: Can you convert Pci/L to PPB
Sent by: International Web Resource for Radon Professionals
All,
I know pCi/l is a measure of radio activity and PPB is a measure of volume.  However is it possible to convert from one to the other?  I found an article here that Is for Strontium 90 but I am not sure if it is a correct formula.  It is also in pCi/G instead of pCi/L.  I would ultimately like to know that 1 pCi/L = “X” PPB.
 
Any help would be appreciated.
 
-Tony McDonald
 
 